Veteran Owned · 3M™ Preferred Installer Certified Las Vegas · 702-803-0283
Home / 3M fire ratings / 3M DI-NOC Architectural Finishes
3M fire ratings · Architectural film

3M DI-NOC Architectural Finishes: fire rating

Every fire result 3M publishes for this film, the substrate the specimen was mounted on, and whether each rating is a test of this product. Best evidence basis across its rows: Tested — the basis is per row, so read the standard beside it.

Compiled & verified 2026-08-09 from 3M-authored documents

These are 3M's published results, not our testing. For a permit or a fire marshal, request the current certificate for your product and lot. Nothing here replaces the authority having jurisdiction's approval. We install film; we do not certify it.

Every rating on file

StandardResultSpecimen mounted on Evidence basisSource
ASTM E84 via NFPA 101 (US)The technical data sheet states that most products are Class A. No flame-spread or smoke index numbers and no test substrate are given; marine, fire-door and Canadian certifications are referred to 3M Technical Service.Not statedNot published3M DI-NOC Architectural Finishes — Technical Data Sheet, Revision S (March 2024)
EN 13501-1:2019-05 (EU)Reaction to fire Class B-s1,d0, tested to EN 15102 for decorative wall coverings. Covers the AE through WG series but explicitly excludes EX-suffix and DG-suffix products.Per EN 15102 decorative wall covering mountingTested3M — Declaration of Performance No. 3M DI-NOC-8, EU Regulation 305/2011 (5 March 2025)

Two documents, two different classification systems, and they are not interchangeable. The EU declaration is the one with a specific class in it — and it excludes the EX- and DG-suffix products.

What to hand a fire marshal

  • EN 13501-1:2019-05 (EU) (Tested): the report cited in that row tests this product to that standard — hand it over when that standard is the one the fire marshal asked for (a slip or EU test does not answer an ASTM E84 request). A named third-party report tests this exact product.
  • ASTM E84 via NFPA 101 (US) (Not published): there is no published result to hand over — request the current certificate for your product and lot from 3M before the install date. The current bulletin states no fire result and refers the question to 3M or the online catalog. Absence of a number in the document is not a failing grade — it means you must request the certificate for your lot.

This film is one of 16 in the 3M Graphic Film Fire-Rating Matrix, which explains the three evidence bases and the ASTM E84 classes. What the building will accept is the other half of the question: the Venue Graphics-Rules Index covers flame-certification rules at 34 U.S. convention venues.

Free quote · Las Vegas

Need this film installed where a fire marshal will look?

Send the venue, the surface and the deadline — we'll spec film with the certification your AHJ wants and install it.

Got a wall, window, or whole convention to cover?

Veteran-owned, 3M-certified, and built for Vegas deadlines.