Veteran Owned · 3M™ Preferred Installer Certified Las Vegas · 702-803-0283
Home / 3M fire ratings / 3M Controltac Plus 180C-10 and 180-10
3M fire ratings · Wrap and wall vinyl

3M Controltac Plus 180C-10 and 180-10: fire rating

Every fire result 3M publishes for this film, the substrate the specimen was mounted on, and whether each rating is a test of this product. Best evidence basis across its rows: Tested — the basis is per row, so read the standard beside it.

Compiled & verified 2026-08-09 from 3M-authored documents

These are 3M's published results, not our testing. For a permit or a fire marshal, request the current certificate for your product and lot. Nothing here replaces the authority having jurisdiction's approval. We install film; we do not certify it.

Every rating on file

StandardResultSpecimen mounted on Evidence basisSource
ASTM E84-00aFlame Spread 5 · Smoke Developed 5 — Class I (A)Three 2 ft × 8 ft × 1/4 in glass-reinforced cement board sections, self-supportingTested3M — Product Flammability Information, Controltac Plus 180C-10 (Omega Point Laboratories report 15300-109509, tested 17 Sep 2001)
ASTM E84-11aFlame Spread 10 · Smoke Developed 10 — Class I (A)1/4 in fiber-reinforced cement board, Grade IITested3M — Product Flammability Information, 180-10 White (Commercial Testing Company report 11-12111, 20 Dec 2011)

Two separate reports exist, a decade apart, on two slightly different cement-board specifications — a useful illustration that an E84 number is a result for one specimen build, not a property of the film.

What to hand a fire marshal

  • ASTM E84-00a, ASTM E84-11a (Tested): the report cited in that row tests this product to that standard — hand it over when that standard is the one the fire marshal asked for (a slip or EU test does not answer an ASTM E84 request). A named third-party report tests this exact product.

This film is one of 16 in the 3M Graphic Film Fire-Rating Matrix, which explains the three evidence bases and the ASTM E84 classes. What the building will accept is the other half of the question: the Venue Graphics-Rules Index covers flame-certification rules at 34 U.S. convention venues.

Free quote · Las Vegas

Need this film installed where a fire marshal will look?

Send the venue, the surface and the deadline — we'll spec film with the certification your AHJ wants and install it.

Got a wall, window, or whole convention to cover?

Veteran-owned, 3M-certified, and built for Vegas deadlines.